Single phase 230V 50 Hz Two pole Insulation class – E, IP54 Protection 230V 50 Hz Two pole Insulation class – E, IP54 Protection
|
MOTOR MODEL |
STARTING METHOD |
OUT PUT |
FRAME SIZE |
SPEED rpm |
FULL LOAD CURRENT Amp. (230V)
|
LOCKED ROTOR CURRENT Amp. |
EFFICIENCY (%) |
POWER FACTOR |
|||||
HP |
KW |
FL |
¾ L |
½ L |
FL |
¾ L |
½ L |
||||||
|
0.3-2-1 |
* 1
|
0.3 |
0.22 |
BG63-2/60 |
2852 |
2.0 |
7.3 |
50 |
46 |
44 |
0.98 |
0.96 |
0.94 |
|
0.5-2-1
|
1
|
0.5 |
0.37 |
BG71-2/50 |
2875 |
2.7 |
10.0 |
59 |
54 |
46 |
0.97 |
0.95 |
0.93 |
|
0.75-2-1 |
1 |
0.75 |
0.55 |
BG71-2L/65 |
2845 |
3.7 |
14.1 |
64
|
64 |
59
|
0.95
|
0.92
|
0.90
|
|
0.75-2-1 |
2
|
0.75 |
0.55 |
BG71-2L/65 |
2845 |
3.7 |
18 |
65 |
58 |
48 |
0.98 |
0.96 |
0.95 |
|
1-2-1 |
2
|
1.0 |
0.75 |
BG80-2/60 |
2853 |
4.8 |
17 |
72
|
67 |
54 |
0.96 |
0.94 |
0.91 |
|
1.5-2-1 |
2
|
1.5 |
1.1 |
BG80-2L/80 |
2864 |
6.7 |
23 |
74 |
74 |
63 |
0.99 |
0.97 |
0.95 |
|
2-2-1 |
2
|
2.0 |
1.5 |
BG90-2S/75 |
2922 |
8.6 |
34 |
77 |
76 |
72 |
0.99 |
0.96 |
0.94 |
|
3-2-1 |
2
|
3.0 |
2.2 |
BG90-2L/100 |
2900 |
13.7 |
45 |
74 |
72 |
66 |
0.99 |
0.97 |